Project Description

 15ft A60 pressurized containers specification

This 15ft A60 zone 2 mud logging unit has been verified , the design ,supply and fabrication has been inspected &tested to comply with DNV 2.7-1 , IEC60079-13.IEC60079-14.

Technical Data

Dimension 4572mmx2438mmx2896mm
Max gross mass 7000kg
Main power Supply 220v,3ph+PE,50hz/60hz
Protection A-60fire rated ,positive pressurization , intended for zone 2 hazardous areas use.

Container body:

Solas A60 Fire rated insulation panel system lining

  1. 1 x Full 50mm A60ROCK WOOL insulation fix inside to the containerwall,
  2. Aluminiumsheet cover A60 rock wool with the pins and locks.
  3. B15 panel outside

1xSolas A60 air tight doors.(800×2000)

1 X Insulated emergency escape hatch(800×800) fitted to the side of the container

1set Grey anti-static PVC floor cover the container floor.

2x A60 windows with 915mmx915mm

ELECTRICAL INSTALLATION:

1xPower inlet junction box for 230V /3PH /60HZ

Step down transformers 440 / 380 / 220 and 110 V

ELECTRICAL INSTALLATION:

1xPower inlet junction box for 230V /3PH /60HZ

Step down transformers 440 / 380 / 220 and 110 V

Equipment installed:

1 x 5 leg lift slings (wire rope)

1x unit Automatic Fire Warning

2x units Fire dampers.

1x unit pressure sensor

1xunit fire Alarm sensor

1x unit Optic gas detector installed in air duct (CH-4 detector)

2x unit Optic gas detector installed in internal room/ air lock (H2S detector)

1xpackage HVAC system

1xCPFG system panel

1x distribution box

1x unit Fan duct with stainless steel with 1 phase Ex fan

1x unit Emergency light 2x36w with Swith

2x units Ex 4ft roof light (2x36w)

1xunit  Ex 2ft roof light (2x26W)

4x unit workbench

4X Swivel chairs mounted to the floor of the container-

8x 110v sockets up the workbench

4cat6 plug

Ex- phone/ MCT/ ATEX junction box / Fire extinguishers